mirror of
				https://xff.cz/git/u-boot/
				synced 2025-10-31 18:35:42 +01:00 
			
		
		
		
	The ESM (Error Signal Monitor) is used on certain PMIC versions to handle error signals propagating from rest of the system. If these reach the PMIC, it is typically a last resort fatal error which requires a system reset. The ESM driver does the proper configuration for the ESM module to reach this end goal. Initially, only TPS65941 PMIC is supported for this. Signed-off-by: Tero Kristo <t-kristo@ti.com>
		
			
				
	
	
		
			20 lines
		
	
	
		
			437 B
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
			
		
		
	
	
			20 lines
		
	
	
		
			437 B
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
| PMIC ESM Binding
 | |
| ======================
 | |
| 
 | |
| Certain Power Management ICs contain safety handling logic within them,
 | |
| allowing automatic reset of the board in case a safety error is signaled.
 | |
| For this purpose, ESM (Error Signal Monitor) is implemented within
 | |
| the PMIC running its own state machine.
 | |
| 
 | |
| Required properties :
 | |
| - compatible	: "ti,tps659413-esm"
 | |
| 
 | |
| Example
 | |
| =======
 | |
| 
 | |
| &tps659413a {
 | |
| 	esm: esm {
 | |
| 		compatible = "ti,tps659413-esm";
 | |
| 	};
 | |
| };
 |